Andévalo Híbrido

Needs attention

Andalusia · Wind + solar + storage · 73 MW installed · 9 technicians · manager Darragh Grealish

Output now

4.2 MW

Load factor

6 %

Energy today

212 MWh

Availability

96.6 %

Producing

21 / 26

Open alarms

6

Generation
Last 12 hours
Wind, solar and battery power at the point of interconnection. A charging battery shows below zero.
Conditions
Resource and grid

Wind

10.4 m/s NNW

Irradiance

261 W/m²

Temperature

22.5 °C

Cloud cover

24 %

Conditions

Sunny intervals

Substation

Puebla SE 400 kV

Voltage

399.4 kV

Frequency

50.020 Hz

Power factor

0.976

Curtailment

0 %

Day-ahead price

108.00 €/MWh

Assets

26 assets on site. Open one for its live 3D view.

Power flow

Wind turbine

WTG-01

Siemens Gamesa SG 6.6-170 · 5.0 MW

Producing
1%

Output

0.05 MW

Today

19.0 MWh

Wind

4.6 m/s

Wind turbine

WTG-02

Siemens Gamesa SG 5.0-145 · 5.0 MW

Standby
0%

Output

0.00 MW

Today

21.1 MWh

Wind

6.3 m/s

Wind turbine

WTG-03

Nordex N163/5.X · 6.2 MW

Producing
52%

Output

3.25 MW

Today

22.6 MWh

Wind

9.9 m/s

Wind turbine

WTG-04

Nordex N149/4.0-4.5 · 5.0 MW

Producing
1%

Output

0.03 MW

Today

19.1 MWh

Wind

4.2 m/s

Wind turbine

WTG-05

Nordex N163/5.X · 5.0 MW

Producing
1%

Output

0.03 MW

Today

17.7 MWh

Wind

4.3 m/s

Wind turbine

WTG-06

Vestas V162-6.2 · 5.0 MW

Producing
5%

Output

0.25 MW

Today

20.2 MWh

Wind

5.9 m/s

Wind turbine

WTG-07

Vestas V162-6.2 · 5.0 MW

Fault
0%

Output

0.00 MW

Today

9.0 MWh

Wind

9.4 m/s

Wind turbine

WTG-08

Siemens Gamesa SG 5.0-145 · 6.2 MW

Producing
17%

Output

1.06 MW

Today

30.4 MWh

Wind

7.6 m/s

Tracker block

PV-01

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
27%

Output

1.10 MW

Today

7.5 MWh

Availability

94.4 %

Tracker block

PV-02

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
24%

Output

0.94 MW

Today

7.4 MWh

Availability

97.3 %

Tracker block

PV-03

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
24%

Output

0.57 MW

Today

3.8 MWh

Availability

96.6 %

Tracker block

PV-04

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
13%

Output

0.32 MW

Today

3.9 MWh

Availability

99.0 %

Tracker block

PV-05

Soltec SF7 · 3.2 MWp

Producing
21%

Output

0.67 MW

Today

5.9 MWh

Availability

94.9 %

Tracker block

PV-06

Soltec SF7 · 3.2 MWp

Producing
15%

Output

0.49 MW

Today

4.8 MWh

Availability

97.3 %

Tracker block

PV-07

Nextracker NX Horizon · 3.2 MWp

Producing
15%

Output

0.49 MW

Today

6.2 MWh

Availability

93.9 %

Tracker block

PV-08

Nextracker NX Horizon · 2.4 MWp

Producing
16%

Output

0.38 MW

Today

3.9 MWh

Availability

97.4 %

Tracker block

PV-09

Array Technologies DuraTrack HZ v3 · 3.2 MWp

Producing
16%

Output

0.52 MW

Today

5.4 MWh

Availability

94.7 %

Tracker block

PV-10

Nextracker NX Horizon · 2.4 MWp

Standby
0%

Output

0.00 MW

Today

4.2 MWh

Availability

98.5 %

Inverter skid

INV-01

SMA Sunny Central 4600 UP · 3.1 MVA

Producing
15%

Output

0.45 MW

Today

8.3 MWh

Availability

97.2 %

Inverter skid

INV-02

Huawei SUN2000-215KTL · 4.6 MVA

Standby
0%

Output

0.00 MW

Today

10.4 MWh

Availability

97.0 %

Inverter skid

INV-03

Sungrow SG3125HV-MV · 3.1 MVA

Producing
41%

Output

1.27 MW

Today

10.0 MWh

Availability

96.6 %

Inverter skid

INV-04

Sungrow SG3125HV-MV · 5.0 MVA

Producing
9%

Output

0.47 MW

Today

11.7 MWh

Availability

95.4 %

Inverter skid

INV-05

Huawei SUN2000-215KTL · 4.6 MVA

Producing
15%

Output

0.69 MW

Today

11.5 MWh

Availability

98.3 %

Inverter skid

INV-06

Huawei SUN2000-215KTL · 3.1 MVA

Maintenance
0%

Output

0.00 MW

Today

5.6 MWh

Availability

98.5 %

Battery container

BESS-01

Tesla Megapack 2XL · 5.0 MW

Producing
70%

Output

3.50 MW

Today

0.0 MWh

State of charge

85 %

Battery container

BESS-02

CATL EnerOne+ · 3.9 MW

Producing
62%

Output

2.42 MW

Today

0.0 MWh

State of charge

85 %

Alarms
Site alarms
Most recent events from this site's assets.

Service interval exceeded

WTG-05· 11-17 10:16
Medium

Soiling loss above threshold

PV-05· 11-17 09:45
Medium

Blade ice detected

WTG-07· 11-17 06:47
High

Soiling loss above threshold

PV-08· 11-17 05:07
Low

IGBT temperature high

INV-06· 11-16 21:22
Medium

Row stowed – high wind

PV-06· 11-16 19:11
Medium