Alcázar Solar

Needs attention

Castilla-La Mancha · Solar PV · 35 MW installed · 4 technicians · manager Thomas Winter

Output now

4.9 MW

Load factor

14 %

Energy today

53 MWh

Availability

95.7 %

Producing

14 / 18

Open alarms

6

Generation
Last 12 hours
Wind, solar and battery power at the point of interconnection. A charging battery shows below zero.
Conditions
Resource and grid

Wind

4.5 m/s SSE

Irradiance

275 W/m²

Temperature

19.4 °C

Cloud cover

21 %

Conditions

Sunny intervals

Substation

Alcázar SE 220 kV

Voltage

219.1 kV

Frequency

50.035 Hz

Power factor

0.988

Curtailment

6 %

Day-ahead price

68.91 €/MWh

Assets

18 assets on site. Open one for its live 3D view.

Power flow

Tracker block

PV-01

Soltec SF7 · 2.4 MWp

Producing
24%

Output

0.57 MW

Today

4.2 MWh

Availability

94.8 %

Tracker block

PV-02

Nextracker NX Horizon · 4.0 MWp

Producing
25%

Output

0.98 MW

Today

6.0 MWh

Availability

95.0 %

Tracker block

PV-03

Nextracker NX Horizon · 2.4 MWp

Producing
21%

Output

0.49 MW

Today

3.9 MWh

Availability

93.8 %

Tracker block

PV-04

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
12%

Output

0.30 MW

Today

3.6 MWh

Availability

98.3 %

Tracker block

PV-05

Soltec SF7 · 3.2 MWp

Producing
11%

Output

0.34 MW

Today

4.5 MWh

Availability

97.3 %

Tracker block

PV-06

Soltec SF7 · 4.0 MWp

Standby
0%

Output

0.00 MW

Today

6.1 MWh

Availability

94.4 %

Tracker block

PV-07

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Standby
0%

Output

0.00 MW

Today

4.0 MWh

Availability

97.3 %

Tracker block

PV-08

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
18%

Output

0.44 MW

Today

4.2 MWh

Availability

93.7 %

Tracker block

PV-09

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Curtailed
8%

Output

0.18 MW

Today

1.9 MWh

Availability

94.5 %

Tracker block

PV-10

Soltec SF7 · 4.0 MWp

Producing
16%

Output

0.65 MW

Today

6.4 MWh

Availability

93.9 %

Tracker block

PV-11

Nextracker NX Horizon · 3.2 MWp

Producing
18%

Output

0.58 MW

Today

4.2 MWh

Availability

97.4 %

Tracker block

PV-12

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
17%

Output

0.40 MW

Today

4.4 MWh

Availability

94.0 %

Inverter skid

INV-01

Huawei SUN2000-215KTL · 3.1 MVA

Producing
31%

Output

0.95 MW

Today

5.5 MWh

Availability

95.1 %

Inverter skid

INV-02

Huawei SUN2000-215KTL · 5.0 MVA

Producing
26%

Output

1.32 MW

Today

8.5 MWh

Availability

99.1 %

Inverter skid

INV-03

Sungrow SG3125HV-MV · 4.6 MVA

Producing
10%

Output

0.48 MW

Today

7.5 MWh

Availability

98.0 %

Inverter skid

INV-04

Sungrow SG3125HV-MV · 5.0 MVA

Producing
17%

Output

0.84 MW

Today

9.7 MWh

Availability

94.9 %

Inverter skid

INV-05

Sungrow SG3125HV-MV · 5.0 MVA

Fault
0%

Output

0.00 MW

Today

8.8 MWh

Availability

94.8 %

Inverter skid

INV-06

Huawei SUN2000-215KTL · 4.6 MVA

Producing
13%

Output

0.60 MW

Today

8.6 MWh

Availability

96.1 %

Alarms
Site alarms
Most recent events from this site's assets.

Transformer oil level low

INV-05· 11-17 13:46
Medium

DC insulation resistance low

INV-05· 11-17 10:49
Medium

Row stowed – high wind

PV-10· 11-17 04:42
Low

Grid voltage out of band

INV-05· 11-17 04:31
Medium

Grid voltage out of band

INV-01· 11-16 23:43
Medium

Tracker stuck – motor current high

PV-01· 11-16 16:58
Low