DMU-03

DMG MORI DMU 50 (3rd Generation) · Siemens SINUMERIK ONE · Bay 1 · Cell C · s/n DMU50-22211

Live machine view
Five-axis cycle
X/Y/Z, the swivelling B trunnion and the C rotary table follow live telemetry; the door opens when the machine stops. Drag to rotate, scroll to zoom.
Cutting
Effectiveness
OEE this shift
Late (14:00–22:00) · 25 of 30 min running
63%

Availability

84.7%

Performance

74.7%

Quality

100.0%

Current job
WO-24117
Valve block · BH-9021-D

Pieces

11 / 20

Cycle time

6m 35s

This piece

5m 45s elapsed

Operator

Sandro Pereira

Tool

T9 · Ø12 face mill

Tool life left

5%

Finishes

17 Nov 15:15

Losses
Downtime by reason
4.5 minutes lost this shift, biggest first.

Setup / first-off

1.8 min

Tool change

0.9 min

Breakdown

0.6 min

No material

0.6 min

Waiting QA

0.4 min

No operator

0.3 min

Quality
Pieces this shift
Ideal 228 s versus actual 305 s per piece.

Good

4

Scrap

0

Rework

0

OEE per hour · %

Queue
Jobs on this machine (3)
The job on the spindle and everything queued behind it, earliest due date first.

WO-24117

Brunner Hydraulik · BH-9021-D OP30 · Al 6082 · setup 46 min

Late

11/20 · due 17 Nov 01:29

WO-24121

Sandvik Tooling · ST-3390-A OP20 · H13 tool steel · setup 35 min

Queued

0/20 · due 19 Nov 01:29

WO-24125

Hot

Helvetica Medtech · HM-2208-C OP10 · 316L stainless · setup 86 min

Queued

0/12 · due 20 Nov 01:29

Readings
Live telemetry
Polled every 5 seconds · spindle 14,433 h, service in 165 h

Spindle load

75 %

Spindle speed

8,770 rpm

Feed rate

1,643 mm/min

Spindle temp

50.6 °C

Coolant temp

27.4 °C

Coolant pressure

17.3 bar

Vibration

2.04 mm/s

Axis load B

30 %

Axis positions

X

102.2

Y

132.3

Z

-94.6

B

-10.9

C

186.2

Spindle history
Spindle load, speed and vibration

Spindle load · %

Spindle speed · rpm

Vibration · mm/s

Alarms
Alarms (8)

Door interlock opened during cycle

Alarm 6621 · 11-17 13:20

High

B axis drive temperature high

Alarm 1105 · 11-17 12:29

Medium

Tool life expired on T7, change required

Alarm 2019 · 11-17 12:08

Low

Tool life expired on T7, change required

Alarm 2019 · 11-16 12:33

High

C axis following error

Alarm 1188 · 11-16 03:38

Medium

Coolant level low in the tank

Alarm 7014 · 11-15 22:58

High

Coolant level low in the tank

Alarm 7014 · 11-15 22:11

High

Coolant level low in the tank

Alarm 7014 · 11-15 18:15

High