Alcázar Solar

Needs attention

Castilla-La Mancha · Solar PV · 35 MW installed · 4 technicians · manager Thomas Winter

Output now

4.6 MW

Load factor

13 %

Energy today

55 MWh

Availability

95.7 %

Producing

14 / 18

Open alarms

6

Generation
Last 12 hours
Wind, solar and battery power at the point of interconnection. A charging battery shows below zero.
Conditions
Resource and grid

Wind

4.7 m/s W

Irradiance

200 W/m²

Temperature

19.3 °C

Cloud cover

47 %

Conditions

Partly cloudy

Substation

Alcázar SE 220 kV

Voltage

219.8 kV

Frequency

49.969 Hz

Power factor

0.980

Curtailment

6 %

Day-ahead price

72.39 €/MWh

Assets

18 assets on site. Open one for its live 3D view.

Power flow

Tracker block

PV-01

Soltec SF7 · 2.4 MWp

Producing
19%

Output

0.46 MW

Today

4.4 MWh

Availability

94.8 %

Tracker block

PV-02

Nextracker NX Horizon · 4.0 MWp

Producing
23%

Output

0.90 MW

Today

6.3 MWh

Availability

95.0 %

Tracker block

PV-03

Nextracker NX Horizon · 2.4 MWp

Producing
17%

Output

0.40 MW

Today

4.0 MWh

Availability

93.8 %

Tracker block

PV-04

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
13%

Output

0.31 MW

Today

3.7 MWh

Availability

98.3 %

Tracker block

PV-05

Soltec SF7 · 3.2 MWp

Producing
12%

Output

0.38 MW

Today

4.6 MWh

Availability

97.3 %

Tracker block

PV-06

Soltec SF7 · 4.0 MWp

Standby
0%

Output

0.00 MW

Today

6.4 MWh

Availability

94.4 %

Tracker block

PV-07

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Standby
0%

Output

0.00 MW

Today

4.1 MWh

Availability

97.3 %

Tracker block

PV-08

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
17%

Output

0.42 MW

Today

4.3 MWh

Availability

93.7 %

Tracker block

PV-09

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Curtailed
7%

Output

0.18 MW

Today

2.0 MWh

Availability

94.5 %

Tracker block

PV-10

Soltec SF7 · 4.0 MWp

Producing
14%

Output

0.57 MW

Today

6.6 MWh

Availability

93.9 %

Tracker block

PV-11

Nextracker NX Horizon · 3.2 MWp

Producing
19%

Output

0.61 MW

Today

4.4 MWh

Availability

97.4 %

Tracker block

PV-12

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
15%

Output

0.36 MW

Today

4.5 MWh

Availability

94.0 %

Inverter skid

INV-01

Huawei SUN2000-215KTL · 3.1 MVA

Producing
24%

Output

0.74 MW

Today

5.8 MWh

Availability

95.1 %

Inverter skid

INV-02

Huawei SUN2000-215KTL · 5.0 MVA

Producing
22%

Output

1.12 MW

Today

8.8 MWh

Availability

99.1 %

Inverter skid

INV-03

Sungrow SG3125HV-MV · 4.6 MVA

Producing
12%

Output

0.56 MW

Today

7.7 MWh

Availability

98.0 %

Inverter skid

INV-04

Sungrow SG3125HV-MV · 5.0 MVA

Producing
19%

Output

0.95 MW

Today

9.9 MWh

Availability

94.9 %

Inverter skid

INV-05

Sungrow SG3125HV-MV · 5.0 MVA

Fault
0%

Output

0.00 MW

Today

9.0 MWh

Availability

94.8 %

Inverter skid

INV-06

Huawei SUN2000-215KTL · 4.6 MVA

Producing
11%

Output

0.52 MW

Today

8.8 MWh

Availability

96.1 %

Alarms
Site alarms
Most recent events from this site's assets.

Transformer oil level low

INV-05· 11-17 14:14
Medium

DC insulation resistance low

INV-05· 11-17 11:17
Medium

Row stowed – high wind

PV-10· 11-17 05:10
Low

Grid voltage out of band

INV-05· 11-17 04:59
Medium

Grid voltage out of band

INV-01· 11-17 00:11
Medium

Tracker stuck – motor current high

PV-01· 11-16 17:25
Low